Audi Q3: Connections for Quick-Release Coupling on Refrigerant Circuit
	
						
			General Information
	- Only valves and connections that are resistant to 
refrigerant R134a and refrigerant oil must be installed.
- Different connections (outer diameter) for high pressure and 
low pressure side.
- Discharge the refrigerant circuit before removing valves or 
valve inserts.
- Always screw on sealing caps.
Allocation in the vehicle. Refer to 
→ Heating, Ventilation and Air Conditioning; Rep. Gr.87; System 
Overview - Refrigerant Circuit (vehicle-specific 
repair manual).
 WARNING
 
  WARNING
There is a danger of ice-up.
Refrigerant will leak out if refrigerant circuit is 
not discharged.
Refrigerant must be extracted before opening 
refrigerant circuit. If refrigerant circuit is not 
opened within 10 minutes of extraction, pressure may 
form in refrigerant circuit due to evaporation. Extract 
the refrigerant once more.
Connections with Schrader Valve (Needle Valve)
	- -A- Service connection 
(soldered in)
- -B- valve insert (Schrader 
valve or needle valve)
- -C- O-ring (belonging to the 
valve)
- -D- cap with seal
 Note
  
Note
	- After connecting, install the hand wheel for the service 
coupling just far enough into the quick-release coupling adapter 
until the valve is securely opened inside the service connection 
(pay attention to the pressure gauge, do not put too much 
pressure on the valve).
- For removing and installing the valve set
-B- when the refrigerant circuit is 
evacuated, for example, use an adapter from the Refrigerant 
Sockets -T10364-.
- Tighten the valve insert -B- 
very carefully because the tightening specification is very 
small.
- There are different versions of these valves and therefore 
there are different tightening specifications. Valve insert
-B- with a VG5 (5.2 x 0.7 mm, tire 
valve) thread has a tightening specification of 0.4 Nm +- 0.1 Nm; 
a valve insert with a M6 x 0.75 mm thread has a tightening 
specification of 0.9 Nm +- 0.1 Nm, and a valve insert with a M8 x 
1.0 mm thread has a tightening specification of 2.0 Nm +- 0.2 Nm.
- There are different versions of these valves, valve inserts 
and their respective sealing caps. Be sure to use the correct 
valve version and the correct sealing cap allocation. Refer to 
the Parts Catalog.

Connections with Primary Sealing Valve (Ball Valve)
 WARNING
 
  WARNING
Before unscrewing the connection, connect the 
service station and extract the refrigerant. Refrigerant 
circuit must be empty to avoid possible injury.
Connection with High-Pressure Valve
1 - Socket with internal thread (soldered in)
2 - O-ring (version and identification: black or colored. Refer 
to the Parts Catalog)
3 - Valve with an external thread and groove for the O-ring 
(identification: ball valve)
4 - Cap seal
5 - Sealing cap

The service connection on the high pressure side depends on 
the vehicle, not all operating conditions of the A/C system are 
on high pressure (for example on the Audi Q7 e-tron). For this 
reason to check the A/C function in these vehicles the sensor 
installed in the refrigerant circuit must be used. Refer to
→ Heating, Ventilation and Air Conditioning; Rep. 
Gr.87; Refrigerant Circuit and use the Vehicle 
Diagnostic Tester in the "Guided Fault Finding" function.
 Note
  
Note
	- After connecting, install the hand wheel for the service 
coupling just far enough into the quick-release coupling adapter 
until the valve is securely opened inside the service connection 
(pay attention to the pressure gauge, do not put too much 
pressure on the valve).
- For removing and installing the valve 
-3- when the refrigerant circuit is evacuated, for 
example, use an adapter from the Refrigerant Sockets -T10364-.
- There are different versions of these valves (with internal 
or external threads). Therefore the tightening specifications 
can also differ. The valves -3- 
with an M12 x 1.5 mm external thread have a tightening 
specification of 9 Nm +-1 Nm.
- There are different versions of these valves and their 
respective caps. Be sure to use the correct valve version and 
the correct sealing cap allocation. Refer to the Parts Catalog.
READ NEXT:
	
   A/C Refrigerant High Pressure Switch -F23-
  
Note
Switch pressures, removing and installing switches as well 
as switch arrangement and version. Refer to vehicle specific 
refrigerant circu
   
   
 
	
   General Information
 
  Caution
When performing work on refrigerant circuit, observe 
all generally applicable safety precautions and pressure 
container regulations.
The pressures and temp
   
   
 
	
   General Information
  
Note
The laws and regulations listed below are applicable in 
Germany. Different or additional laws and regulations may apply 
in other countries.
The effects of clim
   
   
 
   SEE MORE:
	
    
  WARNING
Danger due to refrigerant coming out under pressure.
Danger of frost bite to skin and other parts of the 
body.
	Extract the refrigerant and immediately open the 
refrigerant circuit after that.
	If the refrigerant was extracted more than 10 
minutes in the past and the re
   
   
 
	
   Overview - Heater and A/C Unit Attachments and Air Intake Housing
1 - Sealing Plug
	Equipment version
2 - Screw
	1.5 Nm
3 - Screw
	1.5 Nm
4 - Air Guide Channel to Left Footwell Vent
5 - Air Distribution Housing
	The